Atrius India Core FHIR Implementation Guide
0.1.0 - ci-build
Atrius India Core FHIR Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Draft as of 2026-08-30 |
{
"resourceType" : "ActivityDefinition",
"id" : "atrius-ad-lab-troponin-cardiac",
"meta" : {
"profile" : [
🔗 "https://atrius.in/fhir/r4/atrius-in/StructureDefinition/atrius-service-order-activitydefinition|0.1.0"
]
},
"language" : "en",
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <table class=\"narrative-table\">\n <tbody>\n<tr>\n\n\n<th colspan=\"2\" scope=\"row\" class=\"row-header\">Metadata</th>\n\n\n</tr>\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Version</th>\n\n\n\n<td class=\"content-container\">0.1.0</td>\n\n\n</tr>\n\n\n\n\n\n\n\n \n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Identifier</th>\n\n\n\n<td class=\"content-container\">urn:oid:1.3.6.1.4.1.66219.1.11.8</td>\n\n\n</tr>\n\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Status</th>\n\n\n\n<td class=\"content-container\">Draft</td>\n\n\n</tr>\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Experimental</th>\n\n\n\n<td class=\"content-container\">true</td>\n\n\n</tr>\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Topic</th>\n\n\n\n<td class=\"content-container\">\n treatment from <a href=\"http://terminology.hl7.org/7.2.0/CodeSystem-definition-topic.html\">http://terminology.hl7.org/CodeSystem/definition-topic</a> \n\n\n</td>\n\n\n</tr>\n\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Steward (Publisher)</th>\n\n\n\n<td class=\"content-container\">Atrius</td>\n\n\n</tr>\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Steward Contact</th>\n\n\n\n<td class=\"content-container\">Atrius</td>\n\n\n</tr>\n\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Description</th>\n\n\n\n<td class=\"content-container\"><div><p>Cardiac troponin for ACS rule-in/rule-out. Serial sampling at 0 and 3 hours when using a high-sensitivity assay for rule-out.</p>\n</div></td>\n\n\n</tr>\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Copyright</th>\n\n\n\n<td class=\"content-container\"><div><p>© Atrius. Illustrative catalog entry; adapt dosing and formulary to local policy.</p>\n</div></td>\n\n\n</tr>\n\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Resource Kind</th>\n\n\n\n<td class=\"content-container\">ServiceRequest</td>\n\n\n</tr>\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Resource Profile</th>\n\n\n\n<td class=\"content-container\"><a href=\"StructureDefinition-atrius-in-servicerequest.html\">Atrius India Core ServiceRequest</a> version: 0.1.0</td>\n\n\n</tr>\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Code</th>\n\n\n\n<td class=\"content-container\">\n Troponin I.cardiac [Mass/volume] in Serum or Plasma\n\n\n</td>\n\n\n</tr>\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Intent</th>\n\n\n\n<td class=\"content-container\">Order</td>\n\n\n</tr>\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Priority</th>\n\n\n\n<td class=\"content-container\">STAT</td>\n\n\n</tr>\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Timing</th>\n\n\n\n<td class=\"content-container\">Count 2 times, Once per 3 hours</td>\n\n\n</tr>\n\n\n\n\n\n\n\n\n\n\n<tr>\n <th colspan=\"2\" scope=\"row\" class=\"row-header\">Generated using version 0.5.4 of the sample-content-ig Liquid templates</th>\n</tr>\n\n </tbody>\n </table>\n</div>"
},
"url" : "https://atrius.in/fhir/r4/atrius-in/ActivityDefinition/atrius-ad-lab-troponin-cardiac",
"identifier" : [
{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:1.3.6.1.4.1.66219.1.11.8"
}
],
"version" : "0.1.0",
"name" : "AtriusLabTroponinCardiac",
"status" : "draft",
"experimental" : true,
"date" : "2026-08-30T18:15:29+05:30",
"publisher" : "Atrius",
"contact" : [
{
"name" : "Atrius",
"telecom" : [
{
"system" : "url",
"value" : "https://atrius.in"
}
]
}
],
"description" : "Cardiac troponin for ACS rule-in/rule-out. Serial sampling at 0 and 3 hours when using a high-sensitivity assay for rule-out.",
"usage" : "Order at presentation when ACS is suspected. Repeat per protocol until rule-in or rule-out is achieved.",
"copyright" : "© Atrius. Illustrative catalog entry; adapt dosing and formulary to local policy.",
"topic" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/definition-topic",
"code" : "treatment"
}
]
}
],
"relatedArtifact" : [
{
"type" : "depends-on",
"display" : "ER Chest Pain Pathway",
"resource" : "https://atrius.in/fhir/r4/atrius-in/PlanDefinition/er-chest-pain-pathway|0.1.0"
}
],
"kind" : "ServiceRequest",
"profile" : "https://atrius.in/fhir/r4/atrius-in/StructureDefinition/atrius-in-servicerequest|0.1.0",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "10839-9",
"display" : "Troponin I.cardiac [Mass/volume] in Serum or Plasma"
}
]
},
"intent" : "order",
"priority" : "stat",
"doNotPerform" : false,
"timingTiming" : {
"repeat" : {
"count" : 2,
"frequency" : 1,
"period" : 3,
"periodUnit" : "h"
}
}
}